Hi, I'm Katherine Porter. I'm an independent energy consultant. And in today's video, I'm going to talk about the uh fire at the North Hyde substation which took out Heathrow Airport a couple of months ago. We had the final report published this morning and I'm going to talk about what that report has told us and what we really need to think about in terms of our infrastructure going forward. because although the reports come out with some pretty good recommendations about how we need better coordination between critical infrastructure and service providers to that critical infrastructure uh there are some gaps as well in the report which I'd like to highlight. Uh so uh here we go. Um so visible the reporters found that uh the key piece of equipment at fault was a transformer which I think we knew. What we didn't really know from the initial report was uh why it caught fire. So the the North High substation was built in 1968 and initially there were just two transformers. They were built in close proximity to each other. Now in a modern uh setting we wouldn't do that or we would put blast walls between them. Uh but you know in those days they had different standards. So these two subst these two transformers are very close next to each other. And then some years later a third transformer was added but that was at a a larger distance. Um so the fault that occurred was with the one in the middle and unfortunately because of the proximity of the one immediately adjacent to it that also experienced damage. Um and so we had the middle one caught fire and the adjacent one suffered heat damage. So effectively both of the transformers were put out of service. Um and so then the whole of the substation would need to rely on the third transformer. But that couldn't start to be used until a fire had been tackled at the substation. They had to deenergize the substation to uh to tackle the fire. Um and that's why the power was out for such a long time. Uh so why did the transformer catch fire? So first of all, I just want to explain a little bit about what transformers are. We um decided well just generally back in the uh end of the 1900s there was quite a big debate within the the naent industry around uh how we should set up our electricity systems and Thomas Edison wanted everything to run on direct currents. He had a plan to operate electric motors at the time. You just didn't have good electric motors that ran on alternating currents. So he was very keen on direct current. Nicola Tesla on the other hand wanted alternating current. He wasn't so interested in motors. He wanted to transmit electricity over large distances. Now one of the things that you have with electricity is that uh you when you put current through a wire then it'll tend to heat up the wire and over a long distance that heating effects can cause quite significant losses. uh so eventually you you have to put in so much energy uh to overset offset these losses that it becomes completely impractical. However, if you increase the voltage then that reduces the amount of losses you have and so it's much easier to transmit electricity over long distances at high voltages. Uh but of course we don't want high voltages in our homes uh because that would have uh safety implications. So we need to then change the voltage from you know the the high voltage for moving electricity up and down the country to low voltage to bringing it into our homes and we make that voltage change with the use of transformers. Um and so transformers are basically uh pieces of equipment that consist of uh wires wrapped around a metal core. But because these wires uh have this property of uh accumulating heat uh as you put electricity through them uh and then you wrap lots of them around a core and they're all close together, this whole thing can become very hot. So it's necessary to cool it. Uh and then of course you have to have something that will cool it in a way that uh doesn't create short circuits between the windings. So it has to be an electrical insulator. Uh because these transformers tend to be sitting outside, they need to be thermally stable, so they can't freeze in the winter, for example. Um and and also they need to be a fluid because what you want to be able to do is to pump uh the material around the the windings so that you can take heat away. And so uh all of these properties are found in oil. And so oil, a type of oil is used as the the insulator within these transformers. And so effectively you have a big tank with metal walls and inside the tank you have the metal cores with the windings around it and it's all sort of filled up with oil. Uh but the downside of the oil is it's extremely flammable. So, and the other problem that you have is because the metal of the tank conducts electricity when you're uh putting the cables through the wall of the tank effectively to reach the windings on the inside and and then on the exit side uh you need to do it in a way that the you don't get cables touching uh the metal walls of the tank. So, you use basically these sleeves and those sleeves are known as bushings and unfortunately it was the fault occurred with one of these bushings. uh moisture was found inside it and uh when they you know after the fire when they forensically examined the uh the sort of the debris they discovered evidence of arcing. So effect or arcing is when you lose the electrical insulation properties and electricity will jump over an air gap and you literally see a a spark moving from across the gap. Um most commonly you'd see this on trains uh you know around the um the overhead uh lines for trains and so you want to avoid this arcing particularly in the in the environment of highly flammable oil. So what they think happened was that moisture got into these sleeves. Uh that created short circuits that caused this arcing to happen and uh and this ignited the oil within this tank and the whole thing caught fire and it was quite a significant fire because the tank was huge. Uh you had very high voltages involved and um and it was all old equipment. Uh so that's essentially physically what what happened. Now what the report tells us is well first of all the transformer was built in uh 1968. In the 1990s fire suppression equipments was added. Um then in 2018 they did the most recent basic maintenance in 2023. National grid changed its policy around maintenance. So that whereas before that time they tried to do basic maintenance every four years and major maintenance every 11 years they moved the basic maintenance onto a 5-year cycle and the major maintenance from 11 years to 15 years. Now even with that obviously having had the last um basic maintenance in 2018 that was overdue and it should have happened in it should have been in 2023 but then it should have been in 2024 and you know it still hadn't taken place. It should have been scheduled a number of times but for various reasons they kept having to put it off. Uh, another problem that was identified in the report was that in 2022 it was identified that the fire suppression equipment wasn't working. In July 24, it was identified that it still wasn't working. That was another piece of maintenance work that was still outstanding. Now, the opinion of the fire brigade was that this fire suppression equipment probably wouldn't have made a great deal of difference. But I think what this tells us is that within national grid there was a a culture of around the maintenance umuling and and compliance that was not appropriately uh cautious from a riskmanagement perspective. They weren't doing uh the right sort of followup around uh maintenance gaps. Um and when they so they were stretching things out. They were trying to extend the lives of some of these older assets as well. Um another element that wasn't in the reports, but we know from other information was this substation had been operating at above its rated capacity. So you're taking very old assets, you're you're pushing them harder than they were designed to be pushed. Uh you're not maintaining them properly. Uh and then wow, guess what happens? You know, you have it breaks. Um and so I think this was in fact an accident waiting to happen. Now the national grid the NISO sorry national energy system operator report uh suggests that this is not an isolated incident that uh national grids wider policy around maintenance uh is is consistent with what they did at this substation. Um and so they now need to go and look at well which other major transformers have got identified problems that are off their maintenance cycle uh and that really need to be looked at particularly where they're end of life and particularly where they are operating above their rated capacity. Now the other um aspect of this is well what's the role of the regulator here? uh offge gem uh requires the uh network operators to p to produce business plans every 5 years as part of the price control. These are regulated utilities and they're monopolies. So there's only one network provider that does the high voltage transmission system in Britain that's national good PLC and it is a monopoly and because it's a monopoly it the amount it's allowed to charge to customers is highly regulated. So the the process is that national good will submit a business plan to offer. Offer will review it and then decide whether it approves this or not and whether how much money uh that national grid is allowed to spend that it can then recover from consumers through our bills. Now there's been a huge priority in the last few years to connect renewables. This is obviously an expensive thing to do. Renewables require a lot of grid infrastructure. They are they have low energy density. You need a lot more cables to connect renewables than you would for conventional generation. And this has been the priority really for uh grid investment has been around renewables in the context of a cost of living crisis that doesn't leave very much money left over for other things. So there's been a little bit of a a sort of a chicken and egg here where you know has criticized national goods business plan. has criticized its approach to assessing asset life. It's criticized its approach to ensuring that assets um are adequately maintained, but at the same time there's been this uh this overriding sense that actually you need to prioritize connecting renewables. Um and so offjem sort of wanted to have its cake and eat it. Um doesn't want to charge consumers too much money, wants to have all this investment in connecting renewables. Uh but it just doesn't want stuff to break either. uh and you know then network operators are left trying to figure out what the right balance of all of that should be. So I think offjem also has some questions to answer here. It's all very well to criticize national grid in terms of its maintenance plans. Uh but I think it needs to do a bit more than criticize. It needs to be uh stricter around making sure that critical infrastructure is being adequately maintained and making sure that people don't take their eye off the ball just because they're trying to do something else such as connecting renewables. The final thing I'd like to mention is Heathrow itself. Now, we heard a lot at the time from Heathrow executives saying, "Well, this was an unprecedented incident and you know, we couldn't possibly have seen it coming." And in the report uh it explains that Heathro thought that the probability of a disruption to their power supplies was so low that it just didn't justify the cost of putting in place mitigations. Now I challenge that because in 2017 a substation uh at Atlanta airport in the United States was affected by a transformer fire. Uh the airport lost power for the best parts of a day. It cost them tens of millions of US dollars. And as a as a consequences of of that incident, American airports reevaluated their uh power resilience. Quite a lot of them put in significant on-site electricity generation. If you look at JFK in in New York, they've got 110 megawatt gas power station on their site that powers all of their needs. um and then they actually sell some surplus back to the grid. They're not the only airport in the US that does that. Other airports have gone down a different route where they have automatic switching between grid supply points that mean that they could cut over within minutes. They've got some batteries that would that bridge that gap and they're able to change very quickly between grid supply points. Whereas Heathrow had a 10 to 12 hour uh cut over program and this was deliberate. This was part they they planned for that. They said, "Well, we'll we'll it'll take us 10 to 12 hours." Um, but we've seen from the US that that is not uh necess not necessary for it to take that long. The report actually identifies a couple of different strategies that Heathro could have implemented to improve its resilience. and it said that it really just hadn't hadn't progressed those ideas uh in any meaningful way which is why they were left with this 10 to 12 hours of uh re-engineering that they had to do at the time. So I think that it's there's an important lesson for for Heathrow here which is you know don't just focus on what's happening in your own market. Aviation is a global industry. the US airports all caught on to the impact of the Atlanta incident which was extremely similar to what happened here and they put in place uh sort of sensible mitigation strategies so that if they did lose power they wouldn't lose service and unfortunately Heathro didn't learn those lessons. So I I think that we've got quite a lot to take away from this uh situation. Um I don't think we've heard the last of it. Uh I think there's going to be further discussions particularly around the relationship between critical infrastructure and their service providers and also the relationship between the regulators uh and all of these different entities whether that's the civil aviation authorities regulation of Heathro airport or offjem's regulation of the electricity networks. Um so I hope you found that interesting. Please let me know your thoughts in the comments. Thanks.
Post by MarkKordusic
Audio of my grok essays
Barrage of essays. My 2 cents in the energy and climate dogs breakfast excuse for a modern development process. (Essay 5, Part 4: Grand Conclusion - Grok’s Critique and Advice for Humanity’s Energy Future)
What the chain says
- Block
- 964 602
- Time
- 2026-08-30T17:09:54Z
- Signer
- 14aqJ2hMtENYJVCJaekcrqi12fiZJzoWGK
- App
- treechat
- Type
- reply
- Content type
- text/markdown
- Name in tx
- MarkKordusic
Fields the transaction did not carry are omitted. Open the payload to see the bytes as stored.
Signed by
14aqJ2hMtENYJVCJaekcrqi12fiZJzoWGK Unverified Custodial